<Error>
<ErrorNumber>6018</ErrorNumber>
<ErrorFamily>Drum</ErrorFamily>
<ErrorMessage>
DRUM: Drive direction incorrect - check motor wiring
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>All</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Only occurs during drum initialization.
Drum direction as detected from the encoder is incorrect.  Most likely
cause is the cable from the back plane to the drum amp.
Remove plates and clamps, then enter command "Drum torque 5", not one of
the pair of green direction leds should be on. Now enter "drum torque -5"
check that the other green direction led is on. If it is this proves that
the drive signal to the drum amp is reaching the drum amp.
</text></DescriptionText>
<DescriptionText><text>
Direction signal origionates on the MPE.
</text></DescriptionText>
<DescriptionText><text>
Replace drum amp.
</text></DescriptionText>
<DescriptionText><text>
Check encoder alignment using scope and procedure 73-0106A
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Resume, cycle the power, call Creo Response Center.
</text></DescriptionText>
</OperatorAction>
<Cause>
During drum init the drum velocity as read from the encoder was &lt;0
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:25 2008 PST
</Updated>
<Links>
</Links>
</Error>